BLYWZ - SOLUTION S0193 EX-3
- MSDS: BLYWZ
- Manufacturer: NALCO CHEMICAL CO
- Product Name: SOLUTION S0193 EX-3
- National Stock Number: 6810-00N024010
Product Identification
Product ID:SOLUTION S0193 EX-3
MSDS Date:05/22/1989
FSC:6810
NIIN:00N024010
MSDS Number: BLYWZ
Responsible Party
NAPERVILLE, IL 60566-1024
US
Emergency Phone: 708-920-1510
Info Phone: 708-305-1000
Preparer: JOHN J. KASPER
Cage: 89524
Contractor
Telephone: (630) 305-1000
Cage: 89524
Ingredients
BROMIC ACID, POTASSIUM SALT
CAS: 7758-01-2
RTECS: EF8725000
Fraction By Weight: <0.1%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN: NON-IRRITATING. NO TOXICITY
STUDIES HAVE BEEN CONDUCTED ON PRODUCT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:FLUSH CONTACTED AREA WITH WATER.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO LABORATORY DRAIN OR SEWER WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:DO NOT TAKE INTERNALLY.
Exposure Controls
Respiratory Protection:RESPIRATORY PROTECTION IS NOT NEEDED.
Ventilation:GENERAL VENTILATION IS RECOMMENDED.
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:N1
Spec Gravity:1.0
pH:NEUT
Solubility in Water:COMPLETELY
Appearance and Odor:COLORLESS LIQUID, NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NOT APPLICABLE.
Disposal
Waste Disposal Methods:IF PROD BECOMES WASTE, IT DOES NOT MEET CRITERIA
OF HAZ WASTE AS DEFINED UNDER RCRA 40 CFR 261, SINCE IT DOES NOT
HAVE CHARACT OF SUBPART C, (I.E. D001 THROUGH D017) NOR IS IT
LISTED UNDER SUBPART D. FLUSH TO LAB DRAIN/SANITARY SEWER WITH
WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.